Short answer: Every mansard needs building regulations approval covering structure, fire safety, stairs, insulation, ventilation, sound and electrics. Approval comes from the council or a registered building control approver, with inspections during the build.
What does structure cover?
New steel beams, floor joists sized for a habitable room, raised party walls, and proof that existing walls and foundations can take the load.
What are the fire safety rules?
Adding a storey to a two-storey house means a protected escape route down the stairs: fire doors to rooms opening onto the stair, mains-wired interlinked smoke alarms on every level, and 30 minutes' fire resistance to the new floor.
What are the stair rules?
A fixed stair with at least 1.9 metres headroom on the centre line for loft stairs, a pitch no steeper than 42 degrees and consistent risers and goings.
What about insulation and ventilation?
New roofs and walls must meet current energy standards, and every new habitable room needs background and purge ventilation; bathrooms need extract fans.
How is compliance confirmed?
Building control inspects at key stages and issues a completion certificate at the end. Keep it: you will need it when you sell or remortgage.